April 27, 2012
by Antonio Howard
(view or download the release notes as a PDF)
Updates
- Updated Common Arc’s Contact Info on Common Arc Reports. (S9)
- Updated program’s calendars for those using the Windows XP operating system. (S9, D1)
- Updated New Bulk Continuity Entry to read as such in an effort to be more informative. (S9)
- Updated Open/Delete Bulk Continuity to read as such in an effort to be more informative. (S9)
Performance Improvements
- Added all possible combinations of P Numbers qualified by welding 15E to 15E on WPS Documents. (S9)
- Added a feature to notify users of potential gaps when qualifying a WPS from a PQR. (S9)
- Updated the Expiration Inspection Report to also show the correct expiration day; month and year were already showing correctly. (S9, D1)
- Added the ability to delete items from the select screen of the open menu using the keyboard’s delete button. (S9, D1)
- Increased the space on some grids (Toughness, Weld Details) to prevent side scrolling. (S9, D1)
Issues Resolved
- Allowed Revised WPSs to be created from existing WPSs. (S9)
- Resolved the issue of Metric Thickness showing the incorrect qualified range when impact testing. This was introduced in 2012.2 when the issue of the metric thickness ranges were resolved. (S9)
- Addressed thickness ranges of WPSs qualified by multiple PQRs when the base metal thickness range is qualified with a gap. (S9)
- The ASME Formatted Document no longer prints Single or Multiple Layer as a label when Multiple/Single Pass is needed. (S9)
- Resolved the issue of Procedure Submittal Notes being removed when there are multiple notes and the last note is left empty. (S9)
- When creating new PQR, WPS, WPQ, and PreWPS documents, the UI would open in a GMAW manual default; this was changed to open in a GMAW semi-auto default. (S9, D1)
- Removed the overlapping AS from the ASME rated check-box on the Base Metals page of the WPS. (S9)